| A : Low-voltage wires for automobiles
V : Vinyl |
 |
 |
|
| USE |
|
Wires used in low voltage circuits
in automobiles (vehicles and motorcycles). |
| FEATURES |
|
General purpose wires for automobiles
; they are used in low voltage circuits
such as starting, charging, lighting,
signal and in strument panel circuits.
Standard: JIS C 3406 |
|
| |
| CONSTRUCTION AND PERFORMANCE |
| |
 |
| |
Nominal
size *1 |
Conductors
(Annealed copper
stranded conductors) |
Insulation |
Overall
diameter |
Conductor
resistance
(20ºC)
(m m) |
Current
limit
(A) *2 |
Approx.
weight
(g/m) |
Standard
length
(m) *3 |
Const-
ruction
(No./
mm) |
Calc-
ulated area
(mm2) |
Outer
diameter
(mm) |
Thic-
kness
(mm) |
Stan-
dard
(mm) |
Max.
(mm) |
| 0.5 |
7/0.32 |
0.5629 |
1.0 |
0.6 |
2.2 |
2.4 |
32.7 |
12 |
10 |
1,000 |
| 0.85 |
11/0.32 |
0.8846 |
1.2 |
0.6 |
2.4 |
2.6 |
20.8 |
16 |
13 |
800 |
| 1.25 |
16/0.32 |
1.287 |
1.5 |
0.6 |
2.7 |
2.9 |
14.3 |
21 |
17 |
600 |
| 2 |
26/0.32 |
2.091 |
1.9 |
0.6 |
3.1 |
3.4 |
8.81 |
28 |
26 |
500 |
| 3 |
41/0.32 |
3.297 |
2.4 |
0.7 |
3.8 |
4.1 |
5.59 |
38 |
40 |
300 |
| 5 |
65/0.32 |
5.228 |
3.0 |
0.8 |
4.6 |
4.9 |
3.52 |
51 |
62 |
200 |
| 8 |
50/0.45 |
7.952 |
3.7 |
0.9 |
5.5 |
5.8 |
2.32 |
66 |
92 |
200 |
| 10 |
7/9/0.45 |
10.02 |
4.5 |
1.0 |
6.5 |
6.9 |
1.84 |
78 |
120 |
(2,500) |
| 15 |
7/12/0.45 |
13.36 |
5.4 |
1.1 |
7.6 |
8.0 |
1.38 |
94 |
160 |
(2,000) |
| 20 |
41/0.80 |
20.61 |
6.1 |
1.1 |
8.3 |
8.8 |
0.887 |
121 |
226 |
(1,500) |
| 30 |
70/0.80 |
35.19 |
8.0 |
1.4 |
10.8 |
11.5 |
0.520 |
168 |
384 |
(1,000) |
| 40 |
85/0.80 |
42.73 |
8.6 |
1.4 |
11.4 |
12.1 |
0.428 |
188 |
462 |
(1,000) |
| 50 |
108/0.80 |
54.29 |
9.8 |
1.6 |
13.0 |
13.8 |
0.337 |
220 |
583 |
(1,000) |
| 60 |
127/0.80 |
63.84 |
10.4 |
1.6 |
13.6 |
14.4 |
0.287 |
243 |
678 |
(1,000) |
| 85 |
169/0.80 |
84.96 |
12.0 |
2.0 |
16.0 |
17.0 |
0.215 |
300 |
924 |
(1,000) |
| 100 |
217/0.80 |
109.1 |
13.6 |
2.0 |
17.6 |
18.6 |
0.168 |
356 |
1,151 |
(1,000) |
 |
| 0.5f |
20/0.18 |
0.5087 |
1.0 |
0.6 |
2.2 |
2.4 |
36.7 |
12 |
9 |
800 |
| 0.75f |
30/0.18 |
0.763 |
1.2 |
0.6 |
2.4 |
2.6 |
24.4 |
15 |
12 |
800 |
| 1.25f |
50/0.18 |
1.273 |
1.5 |
0.6 |
2.7 |
2.9 |
14.7 |
38 |
18 |
600 |
| 2f |
37/0.26 |
1.964 |
1.8 |
0.6 |
3.0 |
3.4 |
9.50 |
51 |
25 |
500 |
| 3f |
61/0.26 |
3.239 |
2.4 |
0.7 |
3.8 |
4.1 |
5.76 |
66 |
40 |
300 |
|
 |
 |
|
| *1 |
|
The "f" in the nominal size column
indicates a flexible conductor with
a finer wire diameter. |
| *2 |
|
The current limit data is for conductor
temperature of 80ºC (maximum allowable
temperature) and an ambient temperature
of 40ºC |
| *3 |
|
Standard packing shapes shall be coils.
However, the products which length are
indicated in ( ) shall be wound
on drums. |
|
| |
| |